Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer

Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer

PE-03190029 Stainless steel crucible  for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 measurements thermal analysis. Manufacturer for Mettler crucibles and sample cups. Mettler Instruments good alternative DSC sample pans. Thermal analysis consumables.

  • item no. :

    CS-PM-141-1
  • Suitable for : PE DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500

  • Material : Stainless Steel

  • Part NO : PE-03190029

  • description

Product Item: Stainless Steel Pans, Covers and O-Rings equivalent to PE 03190029 for DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500 PerKinElmer


Item info :

Type Sample pan /crucible
Suitable for PE DSC 8000, Pyris 1 DSC, Diamond DSC, DSC 8500
Part NO PE-03190029
Include Stainless Steel Pans, Covers and O-Rings

Parameter

operating range of -40° to 300 °C, 60 µL volume, and 24 bar maximum pressure
Material Stainless Steel
QTY/PKG3 1000PCS/Box;
Oring Max Operating temperature

The two kinds of Sealing are applicable for different test requirements, please confirmed specific test requirement before ordering.

250 ° C (O ring with fluoro rubber,with a peak at 80° C of Base line)

180 ° C(O ring with Silicon,can not do the test with oil sample)

Original MADE IN CHINA


Note:
For Sealing Rings, Sillicone material and Fluorine material (CS-PE-X1)are available.


For use on all Pans contain the sample in a sealed environment throughout an experiment. The sealing suppresses the vaporization of a solvent or contains a volatile reaction product, thereby eliminating the effects of the heat of vaporization. 


The capsules should not be heated above 300 °C. Any application requiring the heating beyond 200 °C, or where gaseous decomposition products may be generated, should first be tested outside of the instrument. 


Always use guard ring inserts in conjunction with the sealed capsules PerkinElmer DSC instruments. 


When used on the DSC 8000/8500, Diamond DSC and Pyris 1 DSC autosamplers, requires Platinum Lids for the sample and reference furnaces (B0182981).




Shipping:    We do international shipping for clients.       

 
Special offer:  Most of our crucibles are produced to OEM order, please mark clearly height, bottom diameter, top diameter, wall thickness and any special requirements i.e. lips etc. To speed up quotations please supply a drawing and if appropriate, the name of the system in which they are to be used.


REQUEST A FREE QUOTE

If you have questions or suggestions,please leave us a message,

related products
REQUEST A FREE QUOTE

If you have questions or suggestions,please leave us a message,

  • CS PINTEREST
  • CS LINKEDIN
  • CS YOUTUBE
  • CS Facebook

Copyright © 2000-2025 CS Ceramic Co.,Ltd.All Rights Reserved.

   

the professional team to service !

chat now

live chat

    Leave a message and we'll get back to you via email. Normal live chat hours are Mon-Fri 9a-5p (EST)