Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups) Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups) Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups) Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups) Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups)

Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901 for TA Instruments Q100/Q10( Sample Cups)

TA Q100/Q10 900793.901/ 900794.901 Liquid sample test on TA Aluminum sample pans for TA instruments. Manufacturer for TA Thermal Analyzer and DSC sample pans.TA Instruments good alternative sample cups.

  • item no. :

    CS-TM-041
  • Suitable for : TA Instruments Q100/Q10

  • Material : Aluminum

  • Part NO : 900793.901/ 900794.901

  • description

Standard Hermetic aluminum sample pan/lid 900793.901/ 900794.901  for TA Instruments  Q100/Q10( Sample Cups)


Item info :


Type  Sample pan /Crucible
Suitable for  TA Instruments  Q100/Q10
Part NO  TA 900793.901/ 900794.901
Sealing Press Kit
 TA 901600.901
Material  Aluminum 
Test Material   Liquid sample test
Temperature Range:  -180°C to 600°C
QTY/PKG  100PCS/BOX ;200PCS/BOX (Both available)
Brand  CS CERAMIC
Original  MADE IN CHINA




Usage:

Aluminum sample pan and cover: applicable for non-volatile solid sample, like polymer and medicine. It’s widely used for melting, crystallization and vitrifaction test of polymer and thermoplasticity material; Sample vessel is bayonet type, not sealed.



Notice :

To ensure heat transfer efficiency between sample and sensor, please select quality sample pan/crucible with suitable temperature range to conduct experiment, so to get the most accurate effect.


Quality sample pan and crucible is helpful to expand DSC application range. With more sample put in large sized sample pan/crucible to measure weak thermal effect, and to get better resolution, light sample pan/crucible with better thermal conductivity can be used.



Hermetic Aluminum Sample Lids 900794.901 For TA Instruments (click to review the video)



Hermetic Aluminum Sample Pan 900793.901 For TA Instruments (click to review the video)



Recommended matching sealing press TA Instruments 901600.901

(click to review the video)



Guide to TGA Pan Selection - TA sample pan, Platinum pan, Aluminum pan, Ceramic Alumina Pan




Size details: 

OEM: All sizes can be customized and can be made into various complex shapes with high dimensional accuracy. Please clearly provide the height, bottom diameter, top diameter, and any special requirements. To speed up the quotation, please provide drawings.

REQUEST A FREE QUOTE

If you have questions or suggestions,please leave us a message,

related products
REQUEST A FREE QUOTE

If you have questions or suggestions,please leave us a message,

  • CS PINTEREST
  • CS LINKEDIN
  • CS YOUTUBE
  • CS Facebook

Copyright © 2000-2024 CS Ceramic Co.,Ltd.All Rights Reserved.

   

the professional team to service !

chat now

live chat

    Leave a message and we'll get back to you via email. Normal live chat hours are Mon-Fri 9a-5p (EST)